Description

This style is used when you are working with the Min./Max. Temperature tool.


Fields

General Tab

Name

Here, you define the name of the style. You cannot leave this field empty; the chosen name must be unique, i.e. not identical to another existing name. Aside from these limitations, you are free to choose any name.

Places after decimal point

Number of post-decimal place holders, which are to be shown.

Thousands delimiter

The digits left of the decimal point will be grouped into thousands.

Show units

The appropriate units will be shown after each numerical value. The units can be adjusted in the Units tab of the Options dialog window.

Show result symbol

The appropriate symbols (dependent on the type of value) will be shown before each numerical value.

Style

Here, you determine whether the label line should be a simple or an orthogonal (right-angle bent) line.

Line

This setting group determines the properties of label lines (color, style, size and type).

Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm.

End Point Markers

Here, you can determine how the end of both label lines should look like. There are two drop down lists that show the different possibilities.

Extended Tab

Show additional properties for minimum temperature

If this option is selected, additional values (fRSi-value, surface humidity and critical room humidities) for the minimum surface temperature are shown - if they are defined.

Room humidity

Here, you can set the humidity of the room which borders the surface edge. This humidity is used for the calculation of the surface humidity and for any condensation zones that are present.

Surface threshold humidity

Here, you can define the critical surface humidity, which is defined for the corresponding room humidity at a minimal temperature.

Show maximum temperature

If this option is activated then the maximum temperature is shown next to the minimum temperature.

Show average temperature

If this option is activated then the average temperature will be shown next to the minimum temperature.

Border

This setting group determines the properties of the surface edge lines (color, style, size and type).

Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm.

Show condensation zone

If this option is activated, a condensation zone will be displayed with a unique line style - only if a condensation zone is present.

Condensation

This setting group determines the properties of condensation zone lines (color, style, size and type).

Note that some of the lines cannot be shown when their thickness exceeds 0.394 mm.