Description
In this dialog window you can define the properties of air cavities according to EN ISO 10077-2. The use of the wizard is explained in detail in tutorial 4.

Felder
Calculate emissivities |
Emissivities (long-wave radiation properties) in the main heat flux direction according to EN ISO 10077-2 should be calculated as average based on the set radiation surface properties by flixo professional. If this option is not activated, the average emissivities have to be defined in the cavity materials. |
Automatic division |
Determines whether air cavities should be divided according to 10077-2 into smaller air cavities: Division of air cavities can have a significant influence on the results of the calculation. According to the standard, only air cavities with outlets smaller than 2mm are allowed to be subdivided into smaller air cavities. |
Ignore existing colors |
Determines whether manually defined, visible boundaries of air cavities to other air cavities with the same properties should be ignored or taken into account in the division calculation. Division of air cavities can have a significant influence on the results of the calculation. According to the standard, only air cavities with outlets smaller than 2mm are allowed to be subdivided into smaller air cavities. |
Marker color |
Color with which additional division points should be highlighted. |
Url: http://www.infomind.ch/bph/en/flixo/manual/version6/index.html?options_cavity.htm