Navigation:  Tutorials > Psi-Value and U-Value Calculations >

Psi-Value 3 Constructions

Print this Topic Previous pageReturn to chapter overviewNext page

Psi-Values with 3 Components are usefully calculated for constructions where 3 components are connected sequentially. Either the same junction construction is used twice (e.g. 2 identical thermal bridges between a mullion and the glazing) or one  junction between 2 components is "thermal bridge free" (e.g. window with panel instead of glazing).

Click on the arrows in the graphic below to navigate in tutorial 5.

 

Summary

A Psi-value with 3 components is defined using the Psi-Value tool 3 Components  by applying 4 mouse clicks. The first two points define the surface line, through which the effective heat flux should be calculated. The third and fourth point (reference points) divide the surface into 3 parts with different U-values. The points are captured if the snap functions  are active (Grid , Guidelines and Objects , cf. menu Arrange).
The type of the Psi-value has to be adjusted in the Properties flyout.The Psi-value type is either twice the same junction construction (this means both has the same Psi-value) or 1 junction with Psi-value and the second junction without Psi-value.
The U-value of the middle component has to be entered in the Properties flyout. You can enter the U-value either directly using the keyboard or using the tool by clicking on the U-value of another file.
You can adjust the other properties of the Psi-value calculation in the Properties flyout.

Click here or on the navigation buttons in the title in order to continue with the tutorial.

 

 

 


Url: http://www.infomind.ch/bph/en/flixo/manual/version6/index.html?tutorial5_psi3.htm